Heating water boiler «Kolvi 1000»

Description

The KOLVI 1000 boiler is a stationary fire-tube hot-water boiler designed for heating water in water heating systems of buildings and structures with forced circulation. It is made as a horizontal cylindrical prefabricated welded structure consisting of a shell with a furnace, a furnace door, a flue gas box, thermal insulation and decorative cladding. On the upper part of the body there are flanged supply and return water pipes and two pipes for mounting safety valves, and in the lower part there is a drainage connection with an external thread. The body is made of carbon steel and includes two shells connected by a pipe board in the front part, and on the other side, each shell has a welded bottom with a gap. Between the shells are seamless steel convection bundle flue pipes. The inner shell forms a dead-end furnace chamber, where the flue gases from the bottom return to the door, pass through the flue pipes with turbulizers to the flue gas box and are discharged through the chimney. The hinged furnace door is protected by heat-resistant concrete, equipped with a viewing window and has a groove for the sealing cord.

The boiler operates on natural gas or liquid fuel (fuel oil, diesel fuel). The high efficiency (up to 93%) is ensured by a multi-pipe flue and optimized water circulation. The boiler is used in stationary and transportable boiler houses of closed heating systems.

Technical characteristics

Parameter name Unit of measurement Meaning.
Rated heat output kW 1100
Boiler operating pressure, not more than MPa (m.p.s.) 0,6 (60)
Natural gas consumption (min/mcf) m³/h 34 / 127
Diesel fuel consumption kg/h 97,9
Max. outlet temperature of boiler water °C up to 115
Min. coolant temperature in the return pipe °C 60
Outlet gas temperature °C 165
Min. pressure at t=95°C/115°C bar 2 / 3
Heating surface м² 25,31
Heat loss through boiler insulation at rated output, not more than % 0,6
Water volume in the boiler л 1100
Efficiency, not less than % 93
Aerodynamic resistance of the boiler mm Hg 78,7
Hydraulic resistance of the boiler at Δt=15°C kPa 5,2
Supply / return DN 125
Safety DN 65 × 2
Drainage inch G1 1/2
Chimney diameter mm 390
Length, no more than mm 2610
Width, no more than mm 1324
Height (including nozzle), not more than mm 1524